Case Report: A dropped probe can lead to a dropped diagnosis - by Tony Forshaw.

By: Probelogic Pty Ltd  26-Sep-2014
Keywords: Ultrasound, Transducer, Probe

An effective Quality Assurance (QA) protocol is a critical component to the quality ultrasound laboratory. QA emphasis has largely been placed on sonographer training and ongoing professional development, with little consideration for evaluation of transducer integrity. Typical routine preventative maintenance programs (carried out by the ultrasound vendors) consist primarily of a visual inspection for probe damage and an electrical leakage safety test. More sophisticated testing protocols may also include the use of a 2D test phantom, however this is not considered a routine test by vendors, nor is it particularly effective for evaluating individual element function [1]. An additional specialized testing procedure is required to assess the proper functioning of the elements, test integrity of the cabling, and assess for delamination of the lens from the transducer elements [2]. Previous research has highlighted the alarming incidence of defective transducers currently in use in clinical practice, estimating it as high as 40% [3]. Transducers may be faulty due to: weak or “dead” elements, delamination of the lens, and/or cable damage. The effect of transducer damage on image quality has also been well described using phantoms, however the difficulty arises in identifying faulty probes during real-life scanning in that the image quality might not appear deteriorated [4]. The sonographer may fail to notice a progressive loss of image quality over time. Additionally wide variation of image quality between patients makes comparison difficult; poor image quality often attributed to the patient rather than the machine, particularly in cardiac imaging. This case describes an instance of misdiagnosed mitral regurgitation observed following serial transthoracic echocardiography with a faulty transducer. Although the 2D image quality was largely unaffected, the severity of MR was grossly underestimated due to a faulty transducer. FirstCall testing of the transducer reported 25 transducer elements (out of an available 96) which were failing to generate a pulse sufficiently. The transducer passed electrical safety and other usual tests as part of the vendor’s routine testing. There was no visible external damage to the transducer. Without the benefit of side-by-side comparison, or an effective transducer testing protocol, the severity of the MR lesion in the current case could have been missed entirely. This report highlights the need for routine testing of transducers, above the level of testing performed as part of a preventative maintenance service. For a full copy of this report including clinical images - Contact us today! For all your ultrasound needs contact ProbeLogic today! 1300 611 503

Keywords: Probe, Transducer, Ultrasound

Other news and updates from Probelogic Pty Ltd

Getting probes repaired from New Zealand just got a whole lot easier! from Probelogic Pty Ltd thumbnail
22-Jun-2015

Getting probes repaired from New Zealand just got a whole lot easier!

Great News! Getting probes repaired from New Zealand just got a whole lot easier! If you are in New Zealand or have a colleague in New Zealand who could benefit from the ProbeLogic service, let us know today. Our New Zealand representative is: Soma Technology Pacific P.O. Box 21885, Henderson, Auckland, 0650 13 Edsel Street, Henderson, Auckland, 0612 New Zealand Phone: +64 (0)800 476627 Mobile: +64 (0)27 2244374


Is the acoustic lens membrane missing on your transducer?? from Probelogic Pty Ltd thumbnail
30-Apr-2015

Is the acoustic lens membrane missing on your transducer??

Is the acoustic lens membrane missing on your transducer??


27-Feb-2015

Echo Guru Interview

Ashley Barker, CEO of ProbeLogic was interviewed by echo guru. An interesting read for all things ultrasound probe care related.


Are the cables or cases of your probes chemically deteriorating? from Probelogic Pty Ltd thumbnail
16-Feb-2015

Are the cables or cases of your probes chemically deteriorating?

This is often recognisable by a strong yellow tinge. This will often soon lead to cracking and damage. Let us


Opening of ProbeLogic Europe Laboratory from Probelogic Pty Ltd thumbnail
28-Nov-2014

Opening of ProbeLogic Europe Laboratory

ProbeLogic have opened their new office in Paris, France!


26-Aug-2014

warranty extension on repairs

Great News! Latest statistics from the performance of our probe repair lab have enabled us to double the warranty coverage on our repairs.


21-Jul-2014

Are you in Melbourne?

Are you in Melbourne? Need your probes tested? Let us know!


21-May-2014

"My probe is not the best, but does it really matter?"

"My probe is not the best, but does it really matter?" A word from our CEO, Ashley Barker: "This is


01-May-2014

Do you test your ultrasound probes with an electrical leakage tester?

ProbeLogic can calibrate all makes and models of electrical leakage testers used in Australia to traceable standards. Contact us today.


Have you noticed that your 3D probe feels oily lately? from Probelogic Pty Ltd thumbnail
15-Apr-2014

Have you noticed that your 3D probe feels oily lately?

Mechanical 3D probes are filled with an oil. Split caps or ruptured internal bladders will result in oil seeping from


ProbeLogic unveils new Smart3D tester for use with 3D ultrasound probes from Probelogic Pty Ltd thumbnail
02-Apr-2014

ProbeLogic unveils new Smart3D tester for use with 3D ultrasound probes

ProbeLogic unveils new Smart3D tester for use with 3D ultrasound probes


Are you Washing/Sterilizing/Disinfecting or cleaning ultrasound transducers?? from Probelogic Pty Ltd thumbnail
14-Mar-2014

Are you Washing/Sterilizing/Disinfecting or cleaning ultrasound transducers??

Severe corrosion of Ultrasound probe connectors


What is our turn around time on probe repairs? from Probelogic Pty Ltd thumbnail
13-Feb-2014

What is our turn around time on probe repairs?

What is our turn around time on probe repairs? JUST A FEW DAYS!!!


A simple technique to test an ultrasound transducer from Probelogic Pty Ltd thumbnail
29-Jan-2014

A simple technique to test an ultrasound transducer

Simple technique to test an ultrasound probe without an acoustic tester.